Substrate Material Copper Cladding Lamination Technologies Drilling Plating Soldermask General Electrical Test Impedance Measurements Laboratory Quality Assurance


  Maximum Board Size: 18" x 22"
FR4
Getek
Polyimide
BT
Nelco 4000-13
Rogers 4003
Rogers 4350
Rogers RO 3003
Duroid 5870
Taconic 6000+RF35
Ohmega Ply


    Minimum Maximum
Inner Layer Plane ¼ oz 5 oz
Signal 3 oz
Outer Layer   1/8 oz 5 oz


Maximum number of layers: Determined by Customer
Maximum board thickness: .500"
Laminate and Pre-preg materials per IPC-4101

Multifunctional FR4, Getek, Polyimide, BT, Gore, Pyralux, Nelco 13, Allied 408, Rogers

Pyralux 4403, Taconics Rogers. Glass types 106,1080,2116,7628

Minimum line width: .003"
Minimum conductor spacing: .003"
Minimum core thickness: .0016"
Minimum dielectric: .0016"
Buried and Blind Vias
Sequential lamination construction
Buried resistors
Impedance Design Engineering support (circuit width/spacing and dielectric thickness)

Smallest mechanical drilled hole size: .006"
Smallest laser drilled hole size: .005"
Minimum slot width size: .020"
Minimum annular ring: .001"
Signal pad larger than hole minimum: .014" inner .012" outer
Plane clearance larger than finished hole: .025"

Maximum Hole Aspect Ratio
Solder mask over bare copper
Hot Air Solder Level
Immersion gold
Immersion silver
Electroless gold
Electrolytic gold (hard and soft)

Meets NASA Outgassing
Per IPC-SM-840
Photo-Imageable: Enthone, DSR 3241
Dry film: Dupont Vacrel 8000 series and Dynachem 5050
Soldermask Colors Red, Green, Blue, Black, Clear
Minimum pad clearance .001" LPI .003" Dry film
Legend Colors White, Black, Red, Blue

Board Dimensions tolerance +/- .005"
Minimum radius .010"
Beveling and Scoring
Edge Milling
Countersinking and counter-boring

Flying probe test compliant with IPC ET-652
CAD net-list testing
Probe testing down to .008"  
Isolation Parameter 2 ohms
Continuity Parameter 10 ohms

Impedance coupons with board serializations
Measurements of individual traces
Single ended and differential impedances
Custom impedance coupons if requested


Cross-section evaluation per IPC-6012
Board Layer Verification
UL Approved E73924
Ionic contamination testing


Quality System modeled to ISO 9002 specifications
In Process Quality Control
Outgoing Quality Control
IPC-A600 and IPC 6012 trained personal
NIST calibrated measurement

 
 
540 S.Pacific St.San Marcos, California 92069-4056
Phone (760) 744-0300 FAX (760) 744-6388
Email: sales@hughescircuits.com
FTP: ftp.hughescircuits.com